You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

231 lines
6.4 KiB

<template>
<div class="address_edit">
<!-- 导航栏 -->
<div class="header_body">
<header-nav :slefBack="true" @goBack="goBack" :titelText="`详情`"></header-nav>
</div>
<!-- 中间 -->
<div>
<!-- <van-cell-group>-->
<van-form @failed="onFailed" @submit="submit">
<!-- <van-field
v-model="submitData.lawEnforcementCode"
label="登记编号"
readonly
/> -->
<van-field
v-model="submitData.enterpriseName"
label="企业名称"
readonly
/>
<van-field
v-model="submitData.linkMan"
label="企业联系人"
readonly
/>
<van-field
v-model="submitData.linkTel"
label="联系人电话"
:rules="[{ validator, message: '请输入正确内容' }]"
readonly
/>
<van-field
v-model="submitData.checkTime"
readonly
label="检查时间"
/>
<van-field
v-model="submitData.checkItem"
label="检查事项"
2 years ago
type="textarea"
rows="1"
autosize
readonly
/>
<van-field
v-model="submitData.checkRequire"
label="检查要求"
2 years ago
type="textarea"
rows="1"
autosize
readonly
/>
<van-field
v-model="submitData.lawEnforcement"
readonly
label="执法部门"
/>
<van-field
v-model="submitData.lawEnforcer"
readonly
label="执法人员"
/>
<van-field
v-model="submitData.lawEnforcerTwo"
readonly
label="执法人员"
/>
<van-field
v-model="submitData.remark"
label="备注"
rows="2"
autosize
type="textarea"
maxlength="50"
placeholder="请输入备注"
show-word-limit
readonly
/>
</van-form>
<!-- </van-cell-group>-->
</div>
<!-- <div class="warp_body">-->
<!-- <van-action-bar>-->
<!-- <van-action-bar-button text="保存" @click="submit" />-->
<!-- </van-action-bar>-->
<!-- </div>-->
<van-popup v-model:show="data.showLawEnforcerFlag" position="bottom" :style="{ height: '30%' }" />
<van-popup v-model:show="data.showTimePicker" position="bottom" :style="{ height: '30%' }" >
<van-date-picker
type="time"
@confirm="onConfirm"
@cancel="data.showTimePicker = false"
/>
</van-popup>
</div>
</template>
<script setup name="register">
import {getEnterpriseLawEnforcement} from '../../api/administrative'
import { reactive, ref } from "vue";
import {getDict} from "../../api/Home";
import {queryLinkageById} from "../../api/linkage";
2 years ago
import {formattedTimeYYYYmmdd} from "@/util/util";
const router = useRouter();
const route = useRoute();
let queryaddressId = ref("");
const data = reactive({
showLawEnforcerFlag:false,
showTimePicker:false,
});
//保存参数
let submitData = reactive({
/** 登记编号 */
lawEnforcementCode:"",
/** 企业名称 */
enterpriseName:"",
/** 企业ID */
enterpriseId:"",
/** 企业联系人 */
linkMan:"",
/** 联系人电话 */
linkTel:"",
/** 检查时间 */
checkTime:"",
/** 检查事项 */
checkItem:"",
/** 检查要求 */
checkRequire:"",
/** 执法部门 */
lawEnforcement:"",
/** 执法部门ID */
lawEnforcementId:"",
/** 执法人员 */
lawEnforcer:"",
/** 执法人员ID */
lawEnforcerId:"",
/** 执法人员2 */
lawEnforcerTwo:"",
/** 执法人员ID2 */
lawEnforcerIdTwo:"",
/** 备注 */
remark:"",
})
const onConfirm = (time) => {
if(time != null) {
var times = time.selectedValues;
submitData.checkTime = times[0] +"-"+ times[1] +"-"+ times[2];
}
data.showTimePicker = false;
};
const validator = (val) => /^1[34578]\d{9}$/.test(val);
const onFailed = (errorInfo) => {
console.log('failed', errorInfo);
};
// 返回
const goBack = () => {
router.go(-1);
};
const setLinkageItem = (id) => {
queryLinkageById({"id": id}, success => {
submitData.checkItem = success.title
},error=>{});
}
const setLinkageGA = (id) => {
queryLinkageById({"id": id}, success => {
submitData.checkRequire = success.title
},error=>{});
}
//初始化参数,获取扫码的企业统一信用编码
onMounted(() =>{
getEnterpriseLawEnforcement(route?.query?.id,success =>{
//跳转企业二维码地址
if(success.success){
submitData.lawEnforcementCode = success.data.lawEnforcementCode;
submitData.lawEnforcement = success.data.lawEnforcement;
submitData.lawEnforcer = success.data.lawEnforcer;
submitData.lawEnforcerTwo = success.data.lawEnforcerTwo;
submitData.checkItem = success.data.checkItem;
submitData.checkRequire = success.data.checkRequire;
submitData.enterpriseName = success.data.enterpriseName;
submitData.linkMan = success.data.linkMan;
submitData.linkTel = success.data.linkTel;
2 years ago
submitData.checkTime = formattedTimeYYYYmmdd(success.data.checkTime);
submitData.remark = success.data.remark;
setLinkageItem(submitData.checkItem);
setLinkageGA(submitData.checkRequire);
}
},error=>{
console.log("登记失败")
})
})
</script>
<style lang="less" scoped>
.address_edit {
display: flex;
flex-direction: column;
height: 100%;
overflow: hidden;
background-color: #f4f4f4;
}
/* vant4的 Toast 和 Popup 样式冲突,会导致 Toast 变成白底 */
.van-popup.van-toast{
background: var(--van-toast-background) !important;
box-sizing: content-box !important;
/* 下面3条css,影响不大 */
transition: all var(--van-duration-fast) !important;
width: var(--van-toast-default-width) !important;
max-width: var(--van-toast-max-width) !important;
}
.van-popup.van-toast .van-toast__icon{
font-size: var(--van-toast-icon-size) !important;
}
</style>